You are here: Products  » Environmental » KPSI Selection Guide » KPSI 300DS

  Search
KPSI Series 300DS Deep Submersible Level Transducer   

The Series 300DS submersible hydrostatic level transducer is specifically designed for small bore applications and to meet the rigorous environments encountered in deep water level measurements. These transmitters provide repeatable, precision depth measurement under most adverse conditions.

Series 300DS Features

  • Custom Level Ranges up to 4614 ft (1408 m) H2O
  • Accuracy of  ±0.5% FS
  • Analog Outputs of 4-20 mA or 0-5 VDC
  • Welded 316 SS Construction
  • Small Diameter, Rugged, and Waterproof
  • Custom Cable Lengths

Series 300DS Applications

  • Ground Water Monitoring
  • Level Control
  • Surface Water Monitoring
  • Down Hole
  • Dewatering

Buy Now

Support

Updates

Application Notes

FAQs

Warranty & Repair Policy

PDF Downloads

Datasheet

Manual

Accessories

Certifications

 

All KPSI Transducers utilize a highly accurate pressure sensor assembly specifically designed for hostile fluids and gases. The assembly is integrated with supporting electronics in a durable waterproof housing constructed of 316 stainless steel. The attached electrical cable is custom manufactured to Pressure Systems’ specifications and includes Kevlar® members to prevent errors due to cable elongation, and a unique water block feature that self-seals in the event of accidental cuts to the cable.

The Series 300DS is CE compliant to EN 61000-6-4:2001 and EN 61000-6-2:2001 and have a IP 68 and NEMA 6P housing protection rating. All KPSI Transducer calibrations are traceable to the National Institute of Standards and Technology (NIST).

Dated 09/08

Parameter
300DS
Units
Comments

LEVEL RANGES

Full Scale Level Ranges (1)

700 thru 4614
(210 thru 1408)

ft H2O
(m H2O)

sealed gage reference
Proof Pressure
1.5
x FS
 
Burst Pressure
2.0
x FS
 

STATIC PERFORMANCE

Static Accuracy (2)
±0.5
% FSO
BFSL method
Resolution
Infinitesimal
   

ENVIRONMENTAL

Wetted Materials
316 SS; Delrin®; Viton®
  Delrin® and Viton® are registered trademarks of DuPont.
Compensated Temp Range
0 to 50
ºC
 
Thermal Error (3)
±0.05
%FSO/ºC
worst case over compensated temperature range
Operating Temp Range

-20 to 60

0 to 50

ºC

ºC

when using polyurethane cable

when using ETFE cable (5)

Protection Rating
IP 68, NEMA 6P
   

ELECTRICAL

Excitation
9 - 30
VDC
for mA and VDC output
Input Current
20
3.5
mA max
for mA output
for VDC output
Output
4 - 20
0 - 5
mA
VDC

options available (4)
Zero Offset
±0.12
< 0.25
mA
VDC
for mA output
for VDC output
Output Impedance

See Loop Resistance diagram page 5 of datasheet
20

ohm

for mA output
for VDC output
Insulation Resistance
100
mega ohm at 50 VDC
Circuit Protection
Polarity, surge/shorted output
   

PHYSICAL

Approximate Weight

0.63 (285)
0.05 (79)

lbs (g)
lbs/ft (g/m)
transducer
cable
Cable
 
Jacket Material


  Pull Strength

  Number of Conductors
 
Conductor Size

Polyurethane (std)
ETFE (6) (opt)

200 (90)

4

22




lbs (kg)



AWG


Tefzel®, Teflon® and Kevlar® are registered trademarks of DuPont.
Cable Seal
Viton® Gland
  for polyurethane cable
for ETFE cable
  1. Intermediate level ranges are available.
  2. Static accuracy includes the combined errors due to nonlinearity, hysteresis and nonrepeatability on a Best Fit Straight Line (BFSL) basis, at 25ºC per ISA S51.1.
  3. Thermal error is the maximum allowable deviation from the Best Fit Straight Line due to a change in temperature, per ISA S51.1.
  4. Custom VDC output levels can be provided up to 2.5 VDC less than the excitation supply voltage.
  5. -20ºC to 50ºC for level ranges <= 100 ft (70m) H2O when using ETFE cable.
  6. ETFE is a fluoropolymer (Teflon® derivative) material, Tefzel® or equivalent

Specifications subject to change without notice.