You are here: Products  » Environmental » KPSI Selection Guide » KPSI 300

  Search
KPSI Series 300 Small Bore Submersible Level Transducer   

The Series 700 family of submersible hydrostatic level transducers is specifically designed to meet the rigorous environments encountered in liquid level measurement and control. They can be configured to perform to specifications under most adverse, reactive conditions.

Series 300

Series 300 Features

  • Custom Level Ranges up to 700 ft (210 m) H2O
  • Accuracy up to ±0.05% FS
  • Analog Outputs of 4-20 mA or VDC
  • Welded 316 SS or Titanium Construction
  • Small Diameter, Rugged, and Waterproof
  • Custom Cable Lengths
  • Optional Lifetime Lightning Protection

Series 300 Applications

  • Ground Water Monitoring
  • Shipboard Use
  • Level Control
  • Surface Water Monitoring
  • Down Hole
  • Dewatering

Buy Now

Support

Updates

Application Notes

FAQs

Warranty & Repair Policy

PDF Downloads

320 Datasheet

330, 335 Datasheet

Manual

Accessories

Certifications

 

All KPSI Transducers utilize a highly accurate pressure sensor assembly specifically designed for hostile fluids and gases. The assembly is integrated with supporting electronics in a durable waterproof housing constructed of 316 stainless steel or titanium. The attached electrical cable is custom manufactured to Pressure Systems’ specifications and includes Kevlar® members to prevent errors due to cable elongation, and a unique water block feature that self-seals in the event of accidental cuts to the cable.  Each transducer is shipped with our latest SuperDry™ Vent Filter that prevents moisture from entering the vent tube for at least one year without maintenance, even in the most humid environments.

These units are designed for installation in a Class I, Division 1, Groups A, B, C, and D, Class II, Division 1, Groups E, F and G, Class III, Division 1 hazardous location when connected to appropriate apparatus such as those manufactured by R. G. Stahl, Inc., and others.  KPSI transducers are type approved by the American Bureau of Shipping (ABS) and are UL, CUL, and FM approved and have a IP 68 and NEMA 6P housing protection rating. The Series 300 is CE compliant to EN 61000-6-4:2001 and EN 61000-6-2:2001.  All KPSI Transducer calibrations are traceable to the National Institute of Standards and Technology (NIST).

Dated 04/09

Parameter

335 (1)

330 (1)
320
Units
Comments

LEVEL RANGES

Full Scale Level
Ranges (2)

5 thru 700
(1.5 thru 210)

ft H2O
(m H2O)
for vented gage reference

N/A

35 thru 700
(10 thru 210)

10 thru 700
(3 thru 210)

ft H2O
(m H2O)
for sealed gage reference

N/A

35 thru 700
(10 thru 210)

ft H2O
(m H2O)
for absolute reference
Proof Pressure
1.5
x FS  
Burst Pressure
2.0
x FS  

STATIC PERFORMANCE

Static Accuracy (3)

±0.05

±0.10
±0.25
%FSO BFSL method
Resolution
Infinitesimal
   

ENVIRONMENTAL

Wetted Materials
316 SS or Titanium; Delrin®
polyurethane or Viton®
  Delrin® and Viton® are registered trademarks of DuPont.
Compensated Temp Range
0 to 50
ºC  
Thermal Error (4)
±0.05 (5)
%FSO/ºC worst case over compensated temperature range
Operating Temp Range

-20 to 60

0 to 50

ºC

ºC

when using polyurethane cable

when using ETFE cable (9)

Protection Rating

IP 68, NEMA 6P

   

ELECTRICAL

Excitation
9 - 30 (9)
2.5 - 10
VDC for mA, VDC
Input Current
20
3.5
mA max for mA output
for VDC output
Output
4 - 20
0 - 5
mA
VDC

options available (6)
Zero Offset
±0.12 (7)
< 0.25
mA
VDC
for mA output
for VDC output
Output Impedance
See Loop Resistance diagram page 7 of datasheet
20
ohm for mA output

for VDC output
Insulation Resistance
100
mega ohm at 50 VDC
Circuit Protection
Polarity, surge/shorted output
   

PHYSICAL

Approximate Weight

0.47 (224)
0.05 (79)

lbs (g)
lbs/ft (g/m)
transducer
cable
Cable
 
Jacket Material


  Pull Strength

  Number of Conductors
 
Conductor Size

Polyurethane (std)
ETFE (10) (opt)

200 (90)

4

22




lbs (kg)



AWG
Tefzel®, Teflon® and Kevlar® are registered trademarks of DuPont.
Cable Seal

Molded Polyurethane
Viton® Gland

  for polyurethane cable
for ETFE cable

LIGHTNING PROTECTION (OPTIONAL) (11)

Life Expectancy
> 1000 operations
   
Peak Clamping Voltage
36 volts
   
Response Time

< 10 nsecs

   

NOTES:

  1. For ranges > 230 ft H2O (70 m H2O), output is 4-20 mA only.
  2. Intermediate level ranges are available.
  3. Static accuracy includes the combined errors due to nonlinearity, hysteresis and nonrepeatability on a Best Fit Straight Line (BFSL) basis, at 25ºC per ISA S51.1.
  4. Thermal error is the maximum allowable deviation from the Best Fit Straight Line due to a change in temperature, per ISA S51.1.
  5. .For ranges < 12 ft H2O (4 m H2O), maximum thermal error is ±0.1% FSO/ºC.
  6. Custom VDC outputs can be provided up to 2.5 VDC less than the excitation supply voltage. Contact Customer Service for VDC output availability.
  7. For ranges <= 5 ft H2O (1 m H2O), zero offset is ±0.25 mA.
  8. . -20ºC to 50ºC for level ranges <= 100 ft (70m) H2O when using ETFE cable.
  9. Intrinsic safety limits excitation to 28V.
  10. ETFE is a fluoropolymer (Teflon® derivative) material, Tefzel® or equivalent
  11. The power supply needs to be limited to 150 mA to avoid lock up of the gas tube after a suppression event.

Specifications subject to change without notice