NetScanner™ Model 9046 Ethernet Intelligent Temperature Scanner

The Model 9046 Intelligent Temperature Scanner is a completely self-contained high-performance temperature acquisition module for multiple measurements of multiple devices. The 9046 can be configured to read thermocouples, RTDs (385 and 7990), thermistors, voltage signals and/or resistance. The scanner integrates 16 individual uniform temperature references (UTRs) with a microprocessor in a compact, low cost package.

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
 

9022 All-Media Intelligent Pressure Scanner

 

 

Model 9046 Features

  • Accuracy
    -  ±0.35ºC typical for Thermocouples
    -  ±0.10ºC typical for RTDs
    -  ±0.5 mV for Voltages
  • Throughput Rates of 10 meas/ch/sec
  • Onboard EU Conversion (mV, Ohms, ºC, ºF)
  • Configurable for any mix of Thermocouple, RTD, Thermistor, Voltage and/or Resistance
  • Open Circuit Detection
  • Fuse Protected Inputs
  • Rugged Splashproof Enclosure
  • Hardware and Software Triggered Data Acquisition

Model 9046 Applications

  • Turbomachinery Test Stands
  • Vehicle Testing
  • Process Monitoring

 

 


Specifications

–––––––––––––-------–
Updates
–––––––––––––-------–
Application Notes
–––––––––––––-------–
FAQ

PDF Downloads
–––––––––––––-------–
Datasheet
–––––––––––––-------–
Manual
–––––––––––––-------–Certifications
–––––––––––––-------–

 


 
 

Each UTR contains its own thermocouple reference in physical contact with both thermocouple/copper junctions. This arrangement guarantees system accuracy even in thermally dynamic environments. The top connection panel can be configured for any mix of thermocouple types and RTDs.  An internal 32-bit microprocessor corrects for sensor zero, span, and nonlinearity errors.


The 9046 provides the capability to sample using three scan lists concurrently at rates up to 10 measurements per channel per second. Temperature data in engineering units is output through a 10 Mbit Ethernet interface using TCP/IP protocol. The Model 9046 Intelligent Temperature Scanner is supplied with startup software for PC compatible computers. Firmware upgrades are made available at no charge via PSI’s website and can be downloaded to the scanner over the Ethernet interface using NUSS.

The Model 9046 Intelligent Temperature Scanner is one component of the NetScannerTM System.  Multiple NetScanner components  measuring a wide variety of parameters and sharing the same command set can be networked to form a distributed intelligent data acquisition system.

 

Date 01/08

 
 
Pressure Systems
34 Research Drive
Hampton, VA 23666
800.678.7226
KPSI Selection Guide Quality Policy
ISO-9001:2000
Receive E-Newsletter
IPC Member Logo WEEE/RoHS Statement
WEEE/RoHS
Statement
 


Home | Environmental Products | Industrial Products | Aerospace Products | Buy Now
KPSI Level and Pressure Selection Guide | Quartzonix Pressure Standard | NetScanner System | System 8400 |
Electronic Pressure Scanners | S8256 System | Miscellaneous Hardware | News Archive
Contact Us | Distributors | Links | Employment | Register | Search