| Parameter |
750 |
Units |
Comments |
LEVEL
RANGES |
| Full Scale
Level Ranges (1) |
10 thru 115
(3 thru 35) |
ft H2O
(m H2O)
|
vented gage reference |
| Proof Pressure
|
1.5 |
x FS |
 |
| Burst Pressure
|
2.0 |
x FS |
 |
|
STATIC PERFORMANCE |
| Static Accuracy (2) |
±0.25 |
% FSO |
BFSL method |
| Resolution |
Infinitesimal |
 |
 |
ENVIRONMENTAL |
| Wetted Materials |
316 S;
Delrin®; Teflon®
PTFE,
polyurethane or Viton® |
 |
Delrin®, Viton® and Teflon®
are registered trademarks of DuPont. |
| Compensated Temp Range |
0 to 50 |
ºC |
 |
| Thermal Error
(3) |
±0.10
|
%FSO/ºC |
worst
case over compensated temperature range |
| Operating Temp Range |
-20 to 60 |
ºC |
 |
|
Protection Rating |
IP 68, NEMA 6P |
|
|
ELECTRICAL |
| Excitation |
9 - 30 |
VDC |
for mA and VDC output |
| Input Current |
20 3.5 |
mA max |
for mA output
for VDC output |
| Output
|
4 - 20
0 - 5 |
mA
VDC |
options available (4) |
| Zero Offset |
±0.20
<0.1 |
mA VDC |
for mA output
for VDC output |
| Output
Impedance |
See Loop Resistance diagram
page 5 of datasheet
<10 |
ohm
|
for mA output
for VDC output |
| Insulation Resistance |
100 |
mega ohm |
at 50 VDC |
| Circuit Protection |
Polarity, surge/shorted output |
 |
 |
PHYSICAL |
| Approximate Weight |
3.5 (1588)
0.05 (79) |
lbs (g)
lbs/ft (g/m) |
transducer
cable |
Cable
Jacket Material
Pull Strength
Number of Conductors
Conductor Size |
Polyurethane (std)
Tefzel® (opt)
200 (90)
4
22 |
lbs (kg)
AWG |
Tefzel®, Teflon® and
Kevlar® are registered trademarks of DuPont. |
| Cable
Seal |
Molded polyurethane
Viton® Gland |
|
for
polyurethane cable
for Tefzel® cable |
TEMPERATURE OUTPUT
OPTION (Available for 4-20 mA output only) |
| Temperature Range |
0 to 50
-20 to 60 |
ºC |
|
|
Temperature Output
Signal |
4 - 20 |
mA |
 |
| Temperature Measurement Accuracy |
±4 |
ºC |
 |