Parameter |
510
|
Units |
Comments |
LEVEL RANGES |
| Full Scale
Level Ranges (1) |
5 thru 230
(1.5 thru 70) |
ft H2O
(m H2O) |
vented gage reference |
|
115 thru 370
(35 thru 113) |
ft H2O
(m H2O) |
absolute reference |
| Proof Pressure
|
1.5 |
x FS |
 |
| Burst Pressure
|
2.0 |
x FS |
 |
STATIC PERFORMANCE |
| Measurement
Accuracy |
| Level |
±0.10 |
%FS TEB(2) |
 |
| Temperature
|
±0.5 |
ºC |
 |
| Excitation |
±0.5 |
VDC |
 |
| Measurement
Resolution |
| Level |
±0.0001 |
% FS |
 |
| Temperature |
±0.001 |
ºC |
 |
| Excitation |
±0.1 |
VDC |
 |
ENVIRONMENTAL |
| Wetted Materials
|
316 SS or Titanium;
Delrin®, polyurethane or Viton® |
 |
Delrin® and Viton® are registered trademarks of DuPont. |
| Compensated
Temp Range |
-20 to 60 |
ºC |
 |
| Operating
Temp Range |
-20 to 60 |
ºC |
 |
| Protection
Rating |
IP 68, NEMA 6P |
|
|
| ELECTRICAL |
| Excitation |
6 - 28 |
VDC |
 |
| Input Current |
8
11
0.5
|
mA
mA
mA |
average current during data acquisition
peak current during data acquisition for addressed sensor (~40mS duration)
Quiescent |
| Interface |
RS-485 |
 |
Modbus-ASCII or RTU protocol
(1200, 2400, or 4800
baud) |
PHYSICAL |
| Approximate Weight |
0.75 (340)
0.05 (79) |
lbs (g)
lbs/ft (g/m) |
transducer
cable |
Cable
Jacket Material
Pull Strength
Number of Conductors
Conductor Size |
Polyurethane (std)
Tefzel® (opt)
200 (90)
4
22 |
lbs (kg)
AWG |
Tefzel®, Teflon® and
Kevlar® are registered trademarks of DuPont. |
| Cable Seal |
Molded polyurethane
Viton® Gland |
|
for polyurethane
cable
for Tefzel® cable |