Parameter

500

501
Units
Comments

LEVEL RANGES

Full Scale Level Ranges (1)

5 thru 230
(1.5 thru 70)

5 thru 50
(1.5 thru 15)

ft H2O
(m H2O)

vented gage reference
Proof Pressure
1.5
x FS
Burst Pressure
2.0
x FS

STATIC PERFORMANCE

MEASUREMENT ACCURACY
Level
±0.05
±0.10
N/A

%FS TEB (2)
%FS TEB (2)

for level ranges > 10 ft (3 m) H2O
for level ranges <= 10 ft (3 m) H2O
N/A
±0.01
±0.1

ft H2O
% of reading

when reading <= 10 ft (3m) H2O
when reading > 10 ft (3m) H2O
Temperature

±0.5

ºC

Excitation

±0.5

VDC

8 to 28
MEASUREMENT RESOLUTION
Level ±0.0001 % FS  
Temperature ±0.001 ºC  
Excitation ±0.1 VDC  

ENVIRONMENTAL

Wetted Materials

316 SSor Titanium; Delrin®,
polyurethane or Viton®

Delrin® and  Viton® are registered trademarks of DuPont.
Compensated Temp Range
0 to 50
ºC
Operating Temp Range
-20 to 60
ºC
Protection Rating

IP 68, NEMA 6P

   

ELECTRICAL

Excitation
6 - 28
VDC
Input Current

8

11


0.5

mA

mA


mA
average current during data acquisition
peak current during data acquisition for addressed sensor (~40mS duration)
Quiescent
Interface

SDI-12
RS-485

version 1.3 SDI-12 protocol

PHYSICAL

Approximate Weight

0.75 (340)
0.05 (79)

lbs (g)
lbs/ft (g/m)
transducer
cable
Cable
 
Jacket Material


  Pull Strength

  Number of Conductors
 
Conductor Size


Polyurethane (std)
Tefzel® (opt)

200 (90)

4

22





lbs (kg)



AWG

Tefzel®, Teflon® and Kevlar® are registered trademarks of DuPont.
Cable Seal

Molded polyurethane
Viton® Gland

  for polyurethane cable
for Tefzel® cable

LIGHTNING PROTECTION (OPTIONAL)

Life Expectancy
> 1000 operations
Peak Clamping Voltage

36 volts

 
Response Time

< 10 nsecs

 
  
(1) Intermediate level ranges are available.
(2) Total error band includes the combined errors due to nonlinearity, hysteresis, nonrepeatability and thermal effects over the compensated temperature range per ISA S51.1.
 

Specifications subject to change without notice.

 


 
Pressure Systems
34 Research Drive
Hampton, VA 23666
800.678.7226
KPSI Selection Guide Quality Policy
ISO-9001:2000
Receive E-Newsletter
IPC Member Logo WEEE/RoHS Statement
WEEE/RoHS