Parameter

335 (1)

330 (1)
320
Units
Comments

LEVEL RANGES

Full Scale Level
Ranges (2)

5 thru 700
(1.5 thru 210)

ft H2O
(m H2O)
for vented gage reference

N/A

35 thru 700
(10 thru 210)

10 thru 700
(3 thru 210)

ft H2O
(m H2O)
for sealed gage reference

N/A

35 thru 700
(10 thru 210)

ft H2O
(m H2O)
for absolute reference
Proof Pressure
1.5
x FS
Burst Pressure
2.0
x FS

STATIC PERFORMANCE

Static Accuracy (3)

±0.05

±0.10
±0.25
%FSO BFSL method
Resolution
Infinitesimal

ENVIRONMENTAL

Wetted Materials
316 SS or Titanium; Delrin®
polyurethane or Viton®
Delrin® and Viton® are registered trademarks of DuPont.
Compensated Temp Range
0 to 50
ºC  
Thermal Error (4)
±0.05 (5)
%FSO/ºC worst case over compensated temperature range
Operating Temp Range

-20 to 60

0 to 50

ºC

ºC

when using polyurethane cable

when using ETFE cable (9)

Protection Rating

IP 68, NEMA 6P

   

ELECTRICAL

Excitation
9 - 30

2.5 - 10
VDC for mA, VDC and non-ratiometric mV output

for ratiometric mV output
Input Current
20
3.5
mA max for mA output
for VDC output
Output
4 - 20
0 - 5
0 - 100 (7)
2.5 - 10
mA
VDC
mV
mV / V

options available (6)
non-ratiometric
ratiometric (range dependent)
Zero Offset
±0.12 (8)
< 0.25
±0.6
mA
VDC
mV
for mA output
for VDC output
for mV output
Output Impedance
See Loop Resistance diagram page 5 of datasheet
< 10
3000 - 5000
ohm for mA output

for VDC output
for mV output
Insulation Resistance
100
mega ohm at 50 VDC
Circuit Protection
Polarity, surge/shorted output
 

PHYSICAL

Approximate Weight

0.47 (224)
0.05 (79)

lbs (g)
lbs/ft (g/m)
transducer
cable
Cable
 
Jacket Material


  Pull Strength

  Number of Conductors
 
Conductor Size

Polyurethane (std)
ETFE (10) (opt)

200 (90)

4

22




lbs (kg)



AWG
Tefzel®, Teflon® and Kevlar® are registered trademarks of DuPont.
Cable Seal

Molded Polyurethane
Viton® Gland

  for polyurethane cable
for ETFE cable
   
(1) Static accuracy includes the combined errors due to nonlinearity, hysteresis and nonrepeatability on a Best Fit Straight Line (BFSL) basis, at 25ºC per ISA S51.1.
(2) Thermal error is the maximum allowable deviation from the Best Fit Straight Line due to a change in temperature, per ISA S51.1.
(3) For ranges < 23 ft H2O (7 m H2O), output is 0-50 mV.
(4) For ranges < 12 ft H2O (4 m H2O), maximum thermal error is ±0.1% FSO/ºC.
(5) For ranges <= 5 ft H2O (1 m H2O), zero offset is ±0.25 mA.
(6) For ranges > 230 ft H2O (70 m H2O), output is 4-20 mA only.
(7) Optional VDC outputs can be provided up to 2.5 VDC less than the excitation supply voltage.
(8) Intermediate level ranges are available.
(9)  -20ºC to 50ºC for level ranges <= 100 ft (70m) H2O when using ETFE cable.
(10) ETFE is a fluoropolymer (Teflon® derivative) material, Tefzel® or equivalent
 



 
Pressure Systems
34 Research Drive
Hampton, VA 23666
800.678.7226
KPSI Selection Guide Quality Policy
ISO-9001:2000
Receive E-Newsletter
IPC Member Logo WEEE/RoHS Statement
WEEE/RoHS
Statement
 


Home | Environmental Products | Industrial Products | Aerospace Products | Buy Now
KPSI Level and Pressure Selection Guide | Quartzonix Pressure Standard | NetScanner System | System 8400 |
Electronic Pressure Scanners | S8256 System | Miscellaneous Hardware | News Archive
Contact Us | Distributors | Links | Employment | Register | Search