Parameter
|
35(1) |
30(1)
|
27
|
28
|
Units
|
Comments
|
| PRESSURE RANGES |
| Full Scale Pressure Ranges (2) |
2 thru 300
(14 thru 2070) |
1 thru 300
(7 thru 2070) |
psi
(kPa)
|
for vented gage
reference |
| N/A |
15 thru 100
(103 thru 609) |
5 thru 2000
(34 thru 13,790) |
psi
(kPa) |
for sealed gage
reference |
| N/A |
15 thru 100
(103 thru 609) |
15 thru 2000
(103 thru 13,790) |
psi
(kPa) |
for absolute
reference |
| Proof Pressure |
1.5
|
x FS
|
 |
| Burst Pressure |
2.0
|
x FS
|
 |
| STATIC PERFORMANCE |
| Static Accuracy (3) |
±0.05 |
±0.10
|
±0.25
|
±0.50
|
% FSO
|
BFSL method |
| Resolution |
Infinitesimal
|
 |
 |
| ENVIRONMENTAL |
| Wetted Materials |
316 SS or Titanium, Viton®
|
  |
Viton® is a registered trademark of DuPont. |
| Compensated Temp Range |
0
to 50
|
°C
|
 |
| Thermal Error
(4) |
±0.05 (5) |
%FSO/°C |
worst case |
| Operating Temp Range |
-20 to 60
|
°C
|
 |
| ELECTRICAL |
| Excitation |
9-30
2.5 - 10
|
VDC |
for mA, VDC and non-ratiometric
mV output
for ratiometric mV output |
| Input Current |
20
3.5
|
mA max |
for mA output
for VDC output |
| Output (9) |
4
- 20
0 - 5
0 - 100 (6)
2.5 - 10
|
mA
VDC
mV
mV / V
|
options available (7)
non-ratiometric
ratiometric (range dependent) |
| Zero Offset |
±0.12
(8)
< 0.1
±0.6
|
mA
VDC
mV
|
for mA output
for VDC output
for mV output |
| Output Impedance |
See Loop Resistance diagram, pg. 7 of datasheet
< 10
3000 - 5000
|
ohm |
for mA output
for VDC output
for mV output |
| Insulation Resistance |
100
|
mega ohm |
at 50 VDC |
| Circuit Protection |
Polarity, surge/shorted output
|
 |
 |
| PHYSICAL |
| Approximate Weight |
0.44 (198)
|
lbs (g) |
transducer |
| TEMPERATURE
OUTPUT OPTION (Not
Intrinsic Safety Approved) |
| Temperature Range |
0 to 50
-20 to 60 |
°C |
available for 4-20mA output versions only |
| Output Signal |
4-20 |
mA |
 |
| Temperature Measurement Accuracy |
±4 |
°C |
not IS approved |
| (1) |
For ranges > 100 psi (690 kPa),
output is 4-20 mA only. |
| (2) |
Intermediate pressure ranges are available. |
| (3) |
Static accuracy includes the combined errors due to nonlinearity, hysteresis and nonrepeatability on a Best Fit Straight Line (BFSL) basis, at 25°C per ISA S51.1. |
| (4) |
Thermal error is the maximum allowable deviation from the Best Fit Straight Line due to a change in temperature, per ISA S51.1. |
| (5) |
For ranges < 5 psi (34 kPa), maximum
thermal error is ±0.1% FSO/°C. |
| (6) |
For ranges < 10 psi (69 kPa), output
is 0-50 mV. |
| (7) |
Custom VDC output levels can be provided
up to 2.5 VDC less than the excitation supply voltage. |
| (8) |
For ranges <=2 psi (14 kPa), zero
offset is ±0.25 mA. |
| (9) |
For ranges < 2 psi (14 kPa), only 4-20 mA output is available. |
Specifications subject to change without