for mA, VDC and non-ratiometric mV
output
for ratiometric mV output
Input Current
20 3.5
mA max
for mA output for
VDC output
Output
4 - 20
0 - 5
0 - 100
2.5 - 10
mA
VDC
mV
mV / V
options available (4)
non-ratiometric
ratiometric (range dependent)
Zero Offset
±0.12
< 0.1
±0.6
mA VDC
mV
for mA output for
VDC output
for mV output
Insulation Resistance
100
mega ohm
at 50 VDC
Circuit Protection
Polarity, surge/shorted output
PHYSICAL
Approximate Weight
0.82 (371)
lbs (g)
(1)
Intermediate pressure
ranges are available.
(2)
Static accuracy includes the combined errors due to nonlinearity, hysteresis and nonrepeatability on a Best Fit Straight Line (BFSL)
basis, at 25ºC per ISA S51.1.
(3)
Thermal error is the maximum allowable deviation from the Best Fit Straight Line due to a change in temperature, per ISA S51.1.
(4)
Optional VDC outputs can
be provided up to 2.5 VDC less than the excitation supply voltage.
Specifications subject to change without notice.
Pressure Systems
34 Research Drive
Hampton, VA 23666
800.678.7226