Esterline Pressure Systems Logo header spacer Pressure Systems Site Map Pressure Systems Home
 
 

KPSI Series 200 Industrial High Pressure Transducer: Specifications

link arrow  return to Series 200 main product page
 
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
 
Parameter
200
Units
Comments

PRESSURE RANGES

Pressure Ranges (1)

2000 thru 15000
(13.80 thru 103.4)

psi
(MPa)

sealed gage and absolute reference
Proof Pressure
1.5
x FS
Burst Pressure
2.0
x FS

STATIC PERFORMANCE

Static Accuracy (2)
±0.50
% FSO
BFSL method
Resolution
Infinitesimal

ENVIRONMENTAL

Wetted Materials
316 SS; Viton®
Viton® is a registered trademark of DuPont.
Compensated Temp Range
-10 to 80
ºC
Thermal Error (3)
±0.05
%FSO/ºC
worst case
Operating Temp Range
-30 to 105
ºC

ELECTRICAL

Excitation
9 - 30

2.5 - 10
VDC
for mA, VDC and non-ratiometric mV output
for ratiometric mV output
Input Current
20
3.5
mA max
for mA output
for VDC output
Output
4 - 20
0 - 5
0 - 100
2.5 - 10
mA
VDC
mV
mV / V

options available (4)
non-ratiometric
ratiometric (range dependent)
Zero Offset
±0.12
< 0.1
±0.6
mA
VDC
mV
for mA output
for VDC output
for mV output
Insulation Resistance
100
mega ohm at 50 VDC
Circuit Protection
Polarity, surge/shorted output

PHYSICAL

Approximate Weight

0.82 (371)

lbs (g)
 
   
(1) Intermediate pressure ranges are available.
(2) Static accuracy includes the combined errors due to nonlinearity, hysteresis and nonrepeatability on a Best Fit Straight Line (BFSL) basis, at 25ºC per ISA S51.1.
(3) Thermal error is the maximum allowable deviation from the Best Fit Straight Line due to a change in temperature, per ISA S51.1.
(4) Optional VDC outputs can be provided up to 2.5 VDC less than the excitation supply voltage.


Specifications subject to change without notice.


 



 
Pressure Systems
34 Research Drive
Hampton, VA 23666
800.678.7226
KPSI Selection Guide Quality Policy
ISO-9001:2000
Receive E-Newsletter
IPC Member Logo WEEE/RoHS Statement
WEEE/RoHS
Statement
 


Home | Environmental Products | Industrial Products | Aerospace Products | Buy Now
KPSI Level and Pressure Selection Guide | Quartzonix Pressure Standard | NetScanner System | System 8400 |
Electronic Pressure Scanners | S8256 System | Miscellaneous Hardware | News Archive
Contact Us | Distributors | Links | Employment | Register | Search