Parameter |
126 |
116 |
Units |
Comments |
LEVEL RANGES |
| Full Scale
Level Ranges (1) |
10 thru 230
(3 thru 70) |
ft H2O
(m H2O) |
vented gage reference |
| Proof Pressure
|
1.5 |
x FS |
|
| Burst Pressure
|
2.0 |
x FS |
 |
STATIC PERFORMANCE |
| Static Accuracy (2) |
±0.10 |
±0.25 |
% FSO |
BFSL method |
| Total Error
Band (3)
|
±0.3 |
%FS TEB |
Total Error from BFSL |
| Resolution |
Infinitesimal |
 |
 |
ENVIRONMENTAL |
| Wetted Materials
|
316 SS or Titanium; Delrin®; polyurethane or Viton® |
 |
Delrin® and Viton® are registered
trademarks of DuPont. |
| Compensated Temp Range
|
0 to
30 |
º
C
|
 |
| Operating Temp Range |
-20 to 60
0 to 50
|
ºC
ºC
|
when using polyurethane cable
when using ETFE cable(4) |
| Protection
Rating |
IP 68, NEMA 6P |
|
|
ELECTRICAL |
| Excitation |
2.0 - 10.0 |
VDC |
|
| Output |
see page 5 of datasheet
|
mV |
ratiometric
and range dependent |
| Zero Offset |
0
- 0.6 |
mV |
at
1.0 mA constant current |
| Output Impedance |
3000 - 5000 |
ohm |
 |
| Insulation Resistance |
100 |
mega
ohm |
at 50 VDC |
PHYSICAL |
| Approximate Weight |
0.44 (198)
0.05 (79) |
lbs (g)
lbs/ft (g/m) |
transducer
cable |
Cable
Jacket Material
Pull Strength
Number of Conductors
Conductor Size |
Polyurethane (std)
ETFE (5) (opt)
200 (90)
4
22 |
lbs (kg)
AWG |
Tefzel®, Teflon® and
Kevlar® are registered trademarks of DuPont.
|
| Cable Seal |
Molded Polyurethane
Viton® Gland |
|
for polyurethane
cable
for ETFE cable |
| (1) |
Intermediate level
ranges are available. |
|
(2) |
Static accuracy includes the combined errors due to nonlinearity, hysteresis and nonrepeatability on a Best Fit Straight Line (BFSL) basis, at 25°C per ISA S51.1. |
| (3) |
Total Error Band (TEB)
includes the combined errors due to nonlinearity, hysteresis, nonrepeatability,
and thermal effects over the compensated temperature range per ISA S51.1. |
| (4) |
-20ºC to 50ºC for level ranges <= 100 ft (70m) H2O when using ETFE cable. |
| (5) |
ETFE is a fluoropolymer (Teflon® derivative) material, Tefzel® or equivalent |